Learn · HVAC

HVAC, in plain English.

Furnaces, heat pumps, AC, ductwork and keeping the house comfortable for less.

The lingo.

AFUE
Annual Fuel Utilization Efficiency, the percent of fuel a furnace turns into heat. An 80 percent furnace vents through a metal flue; a 95 percent condensing furnace vents in PVC and drains condensate.
Air handler
The indoor unit that moves air in a system without a furnace, typically paired with a heat pump. Contains the blower and evaporator coil.
BTU
British thermal unit, the energy to raise a pound of water one degree. Furnace output and AC capacity are both rated in BTUs per hour.
Condenser
The outdoor unit of a central AC or heat pump: compressor, coil and fan. It rejects the heat pulled from inside the house.
Evaporator coil
The indoor coil, usually sitting on top of the furnace, where refrigerant absorbs heat from the air. A dirty or iced coil is a common cause of weak cooling.
Heat pump
An air conditioner that can run in reverse to heat the house. Modern cold-climate heat pumps hold full capacity well below freezing; a backup heat source covers the coldest days.
HSPF2
Heating Seasonal Performance Factor, the heating efficiency rating of a heat pump. Higher is better.
HVAC
Heating, ventilation and air conditioning: the furnace or heat pump, the air conditioner, the ducts, the thermostat and everything that moves and conditions the air in the house.
Manual J
The industry load calculation that sizes heating and cooling equipment from the house's actual insulation, windows, orientation and climate. A Pro who sizes by square footage alone is guessing.
MERV
The filter efficiency rating, 1 to 16 for residential. MERV 8 to 11 balances filtration and airflow; a very high MERV filter in a system not designed for it starves the blower.
Mini-split
A ductless heat pump with a small outdoor unit feeding one or more wall or ceiling units indoors. Efficient, quiet and ideal for additions, garages and houses without ducts.
Refrigerant
The fluid that carries heat between the indoor and outdoor coils. R-410A is being phased out for lower-warming refrigerants such as R-454B and R-32; a system low on refrigerant has a leak, not a thirst.
SEER2
Seasonal Energy Efficiency Ratio, the efficiency rating on a central air conditioner or heat pump under the current federal test. Higher is more efficient; 14 to 15 is minimum, 18 and up is high efficiency.
Short cycling
Equipment that turns on and off every few minutes instead of running full cycles. Causes include oversizing, a bad thermostat, a clogged filter or a failing component.
Static pressure
The resistance the blower works against in the ductwork. High static pressure means undersized or restricted ducts, and it shortens equipment life.
Ton
A measure of cooling capacity, not weight. One ton removes 12,000 BTUs of heat per hour. A typical house needs one ton per 400 to 700 square feet depending on climate and insulation.
Variable speed
Equipment whose compressor or blower runs at many speeds instead of just on or off, holding steadier temperatures and humidity with less energy.
Zoning
Dampers and multiple thermostats that let one system heat or cool parts of the house independently.

Guides.

Reading list.

Articles from around the internet that our Pros trust. They open on the source's site.

  • Central air conditioning · U.S. Department of Energy

    How central AC works, sizing, efficiency ratings and when to replace.

  • Furnaces and boilers · U.S. Department of Energy

    Efficiency ratings, retrofits and replacement of gas and oil heating.

  • Heat pump systems · U.S. Department of Energy

    Air-source, ductless and geothermal heat pumps, and what to expect in cold climates.

  • Indoor air quality · U.S. EPA

    Ventilation, filtration, humidity and the sources of indoor air problems.

From the Pros.

Written by the people who do this work every day, in your area.

The first posts from HVAC Pros are on their way.

Questions from homeowners.

Ask the Pros

No questions yet for HVAC. Yours would be the first, and a Pro will answer it.